Soft starts smart stops. Emotron MSF 2.0 Softstarter

Similar documents
Circuit Simulators: A Revolutionary E-Learning Platform

Application of Virtual Instruments (VIs) for an enhanced learning environment

LEGO MINDSTORMS Education EV3 Coding Activities

MinE 382 Mine Power Systems Fall Semester, 2014

21 st Century Apprenticeship Models

Module 12. Machine Learning. Version 2 CSE IIT, Kharagpur

DEVELOPMENT OF AN INTELLIGENT MAINTENANCE SYSTEM FOR ELECTRONIC VALVES

LABORATORY : A PROJECT-BASED LEARNING EXAMPLE ON POWER ELECTRONICS

ECE-492 SENIOR ADVANCED DESIGN PROJECT

Simulation of Multi-stage Flash (MSF) Desalination Process

CUSTOMER TRAINING COURSE PROGRAMME TECHNICAL TRAINING

EDEXCEL NATIONALS UNIT 25 PROGRAMMABLE LOGIC CONTROLLERS. ASSIGNMENT No.1 SELECTION CRITERIA

Software Maintenance

On Human Computer Interaction, HCI. Dr. Saif al Zahir Electrical and Computer Engineering Department UBC

Reduce the Failure Rate of the Screwing Process with Six Sigma Approach

FUZZY EXPERT. Dr. Kasim M. Al-Aubidy. Philadelphia University. Computer Eng. Dept February 2002 University of Damascus-Syria

SSE - Supervision of Electrical Systems

5.1 Sound & Light Unit Overview

Postprint.

Research at RWTH Aachen University. Turning waste into resources

A Power Systems Protection Teaching Laboratory for Undergraduate and Graduate Power Engineering Education

Five Challenges for the Collaborative Classroom and How to Solve Them

Python Machine Learning

PELLISSIPPI STATE TECHNICAL COMMUNITY COLLEGE MASTER SYLLABUS APPLIED MECHANICS MET 2025

Meeting Agenda for 9/6

Crestron BB-9L Pre-Construction Wall Mount Back Box Installation Guide

Getting Started with TI-Nspire High School Science

CURRICULUM VITAE FOR ANNET NSIIMIRE

Historical maintenance relevant information roadmap for a self-learning maintenance prediction procedural approach

A Practical Approach to Embedded Systems Engineering Workforce Development

week prep Potchefstroom College GCC

AGENDA LEARNING THEORIES LEARNING THEORIES. Advanced Learning Theories 2/22/2016

ENEE 302h: Digital Electronics, Fall 2005 Prof. Bruce Jacob

Beveridge Primary School. One to one laptop computer program for 2018

Education the telstra BLuEPRint

Commanding Officer Decision Superiority: The Role of Technology and the Decision Maker

2.B.4 Balancing Crane. The Engineering Design Process in the classroom. Summary

Scholastic Leveled Bookroom

SOFTWARE EVALUATION TOOL

SAM - Sensors, Actuators and Microcontrollers in Mobile Robots

An Introduction to Simio for Beginners

PRODUCT COMPLEXITY: A NEW MODELLING COURSE IN THE INDUSTRIAL DESIGN PROGRAM AT THE UNIVERSITY OF TWENTE

EEAS 101 BASIC WIRING AND CIRCUIT DESIGN. Electrical Principles and Practices Text 3 nd Edition, Glen Mazur & Peter Zurlis

Infrared Paper Dryer Control Scheme

Power Generation Maintenance Mechanic Level Two

The Application of Lean Six Sigma in Alleviating Water Shortage in Limpopo Rural Area to Avoid Societal Disaster

UK flood management scheme

Here are some helpful steps to guide you in completing the Contributor s Form below:

THE VIRTUAL WELDING REVOLUTION HAS ARRIVED... AND IT S ON THE MOVE!

AC : DESIGNING AN UNDERGRADUATE ROBOTICS ENGINEERING CURRICULUM: UNIFIED ROBOTICS I AND II

Electrical Testing Equipment Performance Rubrics

SimCity 4 Deluxe Tutorial. Future City Competition

Catchy Title for Machine

Steps Before Step Scanning By Linda J. Burkhart Scripting by Fio Quinn Powered by Mind Express by Jabbla

CPMT 1347 Computer System Peripherals COURSE SYLLABUS

Learning Methods for Fuzzy Systems

Utilizing Soft System Methodology to Increase Productivity of Shell Fabrication Sushant Sudheer Takekar 1 Dr. D.N. Raut 2

Use of CIM in AEP Enterprise Architecture. Randy Lowe Director, Enterprise Architecture October 24, 2012

Spring 2015 Achievement Grades 3 to 8 Social Studies and End of Course U.S. History Parent/Teacher Guide to Online Field Test Electronic Practice

DIDACTIC MODEL BRIDGING A CONCEPT WITH PHENOMENA

Graphic Imaging Technology II - Part two of a two-year program designed to offer students skills in typesetting, art and pasteup,

3/6/2009. Residence Halls & Strategic t Planning Overview. Residence Halls Overview. Residence Halls: Marapai Supai Kachina

The role of virtual laboratories in education

The KAM project: Mathematics in vocational subjects*

Friction Stops Motion

ME nd Law Analysis of Engineering Systems

Appendix L: Online Testing Highlights and Script

Modeling user preferences and norms in context-aware systems

Proposal of a PhD Programme (PhD) managed by the Politecnico di Milano. PhD in: STRUCTURAL, SEISMIC AND GEOTECHNICAL ENGINEERING CYCLE: XXIX

MULTIMEDIA Motion Graphics for Multimedia

Computers on Wheels!!

Prototype Development of Integrated Class Assistance Application Using Smart Phone

Measurement. When Smaller Is Better. Activity:

Aclara is committed to improving your TWACS technical training experience as well as allowing you to be safe, efficient, and successful.

Hard Drive 60 GB RAM 4 GB Graphics High powered graphics Input Power /1/50/60

Study Guide for Right of Way Equipment Operator 1

Telekooperation Seminar

Math Pathways Task Force Recommendations February Background

Class of 2018 Junior Proposal for Senior Project. Make the Most of Your Journey

Using a PLC+Flowchart Programming to Engage STEM Interest

Innovative methods for laboratory courses in physics degree programs: the Slovenian experience

USING A RECOMMENDER TO INFLUENCE CONSUMER ENERGY USAGE

Aviation English Solutions

Executive Guide to Simulation for Health

Electronic Reserves: A Centralized Approach to the Scanning Process

Iep Data Collection Templates

Computer Science. Embedded systems today. Microcontroller MCR

Evaluation of ecodriving performances and teaching method: comparing training and simple advice

Dyslexia and Dyscalculia Screeners Digital. Guidance and Information for Teachers

IMPROVED MANUFACTURING PROGRAM ALIGNMENT W/ PBOS

University of Toronto Physics Practicals. University of Toronto Physics Practicals. University of Toronto Physics Practicals

Intel-powered Classmate PC. SMART Response* Training Foils. Version 2.0

Diploma in Library and Information Science (Part-Time) - SH220

TA Certification Course Additional Information Sheet

Multisensor Data Fusion: From Algorithms And Architectural Design To Applications (Devices, Circuits, And Systems)

For the Ohio Board of Regents Second Report on the Condition of Higher Education in Ohio

Teaching a Laboratory Section

Multimedia Courseware of Road Safety Education for Secondary School Students

Computer Software Evaluation Form

Augusta Independent Board of Education August 11, :00 PM 207 Bracken Street Augusta, KY

Transcription:

Soft starts smart stops Emotron MSF 2.0 Softstarter

More than just a soft start Starting an electrical motor involves a number of challenges, such as high start currents and mechanical stress on equipment. This results in high energy, installation and maintenance costs. Emotron MSF handles this and a lot more. Start and stop sequences are optimized. Advanced braking techniques increase productivity. Built-in monitor functionality protects your process. Easy installation and set-up save time and money. A soft-starter beyond the ordinary! Current Emotron MSF with torque control Softstarter with voltage control Y/D start Direct on line (DOL) start 8 7 6 5 I/I N 4 3 2 1 0 DOL start Y/D start Voltage/current control softstarter Emotron MSF torque control softstarter 2 4 6 8 10 Time 2,000 1,000 Speed 5 s 10 s 1,480 rpm Time With an Emotron MSF the start current is up to 30% lower than with a conventional softstarter. Emotron MSF offers efficient torque control that enables you to start more smoothly with constant acceleration.

Ultra-smooth starts reduce your costs Conventional softstarters use a pre-defined voltage ramp to control the start. With Emotron MSF, the actual motor torque is continuously calculated and controlled according to the application requirements. This so called torque control ensures an ultra-smooth start with constant acceleration. The torque control means the start current is reduced even further by up to 30%. You can use smaller fuses and less expensive cables, and will thus benefit from lower installation and energy costs. The smooth starts also lead to less mechanical stress, improved process control and reduced maintenance costs. Controlled starts for efficiency and safety Torque boost can be used to overcome initial torque peaks when starting, for example, a loaded crusher or mill. This will reduce mechanical stress as well as enhance efficiency in your process. Starting a fan which is rotating in the wrong direction due to a draught, will lead to high current peaks and mechanical stress and can result in blown fuses and breakdown. Emotron MSF gradually slows the motor to a complete stop before starting it in the right direction. Damage is prevented and mechanical vibrations are eliminated. The starting direction can be fully controlled, for example of a tunnel fan if there is a fire when controlling the direction of the air flow is critical for safety reasons. Emotron MSF offers full control without the need for an external PLC, thanks to two inputs for start left/right and built-in control of forward/ reverse contactors. You will benefit from simplified installation and reduced investment costs. Protect your process and maximize efficiency The Emotron MSF softstarter has a built-in load monitor that protects your machine and process against costly downtime, equipment damage and break-down. It reacts immediately if a crusher is jammed, a pump is running dry, a compressor is idling, or a fan is operating inefficiently due to a blocked filter. This is achieved by constant viewing of the motor shaft power. Any deviation from your selected load levels will result in a warning or a quick but smooth stop. The actual load can be displayed via, for example, Profibus. The monitor can also be used to determine when a process is ready, for example, when the viscosity is right in a mixing process. You can rely on an efficient and reliable operation protected from damage and interruptions. Smart stops with built-in braking functionality The definition of a smart stop depends on your application. For a pump, the aim is to slowly decrease the flow to prevent mechanical stress on pipes and valves, while a saw often requires a quick stop for security or productivity reasons. The advanced braking techniques of Emotron MSF softstarters meets both challenges just as efficiently. When stopping a pump you can benefit from the same smart principle as when starting it a linear stop using the torque control. You no longer risk water hammer and there is no need for costly equipment such as motor-controlled valves. When a quick stop is needed, the brake functionality of Emotron MSF eliminates the need for expensive and space-consuming external brakes and saves you both investment and maintenance costs. The built-in vector brake is used for handling low braking torque loads. The built-in reverse current brake efficienctly handles high inertia loads in, for example, crusher or mill operation. It s also the solution for band saws and saw applications where extremely short braking times are required. Load Speed Overload stop Overload warning Voltage/current control softstarter Normal load curve Underload warning Underload stop DOL start Y/D start Emotron MSF torquecontrol Time A built-in load monitor protects your process against damage and inefficiency by sending a warning or stopping the process at your chosen load levels. 2 4 6 8 10 12 14 The torque control ensures a linear stop that protects your pump from water hammer. No motor-controlled valves are required. Time

Emotron MSF offers versatile communication options with, for example, a control room. Analogue, digital, serial and fieldbus communication are supported.

Easy to install and easy to use Installation is quick and cost-efficient, since no additional equipment is required. Everything you need is included in the Emotron MSF unit. A number of options let you customize the Emotron MSF functionality and fully utilize the softstarter according to your needs. Quick and cost-efficient installation Installing an Emotron MSF unit is quick and cost-efficient. There is no need for any of the additional equipment usually required to complement soft starter functions DC brakes, motor protection relays, mains failure relays, load monitors, meters, displays or switches. Everything you need is included in the Emotron MSF unit. Programming the settings according to your needs is also quick and easy. Programmable inputs increase flexibility Emotron MSF has four programmable inputs that offer great flexibility and extended functionality. For example, you can control the rotation direction of a fan by programming two inputs for start left and start right respectively. An external alarm signal can be connected to stop the motor if a problem occurs. An analogue sensor can be connected directly to the Emotron MSF to control start and stop levels of a pump. Installation is simplified and investment costs are reduced since no external PLC is required. Up to four different parameter sets can be selected via the programmable inputs. Versatile communication options In many applications, the softstarter is one of several control devices. To enable communication between these devices and with e.g. a control room, Emotron MSF provides versatile communication options: Several process values and system parameters are available via the communication interfaces. These can be used in your control system to achieve optimal performance at minimal cost. Current Voltage Shaft power Energy consumption Power factor Shaft torque Operating time Motor thermal capacity External control panel An external control panel is available as an option. It can be mounted on the front of a panel door or a control cabinet for remote control of the softstarter. Maximum distance between softstarter and external control panel is three metres. Cable kit and cable entry box An optional cable kit can be used together with the bypass function to facilitate connection of external current transformers. A cable entry box makes it possible to mount an Emotron MSF 017-085 using cable glands to attach the cables. Protection class is IP20. Fieldbus communication (Profibus, DeviceNet) Serial communication (RS232, RS485, Modbus) Analogue and digital outputs Ethernet and other communication buses are available via a gateway unit.

APPLICATIONS Pumps Fans Compressors Blowers Crushers Screens Mills Mixers Saws

A wide range to suit your needs TECHNICAL DATA Emotron MSF 2.0 softstarters are available in the following range: Supply voltage 200 690 V, 3-phase Rated current 17 1,650 A Rated power 7.5 1,600 kw Protection class IP20, NEMA 1 (up to 960 A) IP00, NEMA 0 (up to 1,650 A) Approvals CE, UL, GOST R For further technical information, please see the Emotron MSF 2.0 data sheet.

CG Drives & Automation Mörsaregatan 12 Box 222 25 SE-250 24 Helsingborg T + 46 42 16 99 00 F +46 42 16 99 49 info.se@cgglobal.com www.cgglobal.com / www.emotron.com CG Drives & Automation 01-6013-04 2015-03